Pyr0-Piezo Config
Serial Terminal Applications¶
In order to send commands, you will need an application capable of communicating over serial. Please download and install one of the following:
- Windows
- PuTTY
- RealTerm
- Termite
- MacOS
- Linux
- minicom -
sudo apt install minicom
||sudo yum install minicom
Updating Pyr0-Piezo Circuit Parameters over Serial¶
The Pyr0-Piezo onboard microcontroller can be adjusted over UART/TTY/Serial.
To set the below parameters using serial input, use the following:
- To change trigger active duration:
TRG_D [integer for milliseconds]
- To change gain factor:
GAIN_F [integer for gain state - see note*]
- To change the output logic:
LOGIC [0|1]
(0 for active low, 1 for active high) - To enable piezo plugged detection:
PZDET [0|1]
(0 for disabled, 1 for enabled) - To change ADC hysteresis value:
HYST [integer in millivolts]
- To change sensor input pullup vRef low threshold:
VFOL [integer in millivolts]
- To change comparator trigger high threshold:
VCOMP [integer in millivolts]
- To change the duration between ADC measurements:
LOOP_D [integer in milliseconds]
- To update the internal vRef constant value **(see notes below):
CONST [long value]
You can also enable or disable DEBUG output with: DEBUG [0|1]
You can query the current configuration with: CONFIG
You can query the current state (including ADC measurements) with: STATE
To reset all settings to defaults, use: RESET
These commands should be wrapped in this format:
CMD INT
Examples:
GAIN_F 3
<~ set gain factor to index 3 (6x)VFOL 2350
<~ set the vref floor to 2.35VDEBUG 1
<~ Enable debug outputSTATE
<~ display current sensor status
*Note for Gain Factor: The gain STATE is representative of these values:
- 0 = 3x
- 1 = 3.5x
- 2 = 4.33x
- 3 = 6x
- 4 = 11x
Calibrating the internal vRef¶
The adc calculation in this sensor assumes an "ideal" constant value which is used to convert the internal 1.1v reference.
Each Atmega chip is slightly different, so it won't be completely accurate without tuning. Most of the time this won't be necessary, so don't mess with this if you don't know what you're doing!
The reading can be fine-tuned by using a multimeter, and this equation:
scale_constant = internal1.1Ref * 1023 * 1000
where
internal1.1Ref = 1.1 * Vcc1 (per voltmeter) / Vcc2 (per readVcc() function)
If the scale_constant calculated is different from the default 1125300, update the voltMeterConstant variable in pP_config.h with the correct value or use the CONST
command
Configuration in firmware¶
All default configurations are stored in pP_config.h
.
#define GAIN_FACTOR_DEFAULT 2
- Gain adjustment factor. 0=3x, 1=3.5x, 2=4.33x, 3=6x, 4=11x
#define FOLLOWER_THRESHOLD_DEFAULT 1450
- Voltage follower default voltage in millivolts (1/1000V)
#define COMP_THRESHOLD_DEFAULT 2850
- Comparatore Vref default voltage in mV
#define InitCount 6
- Number of times to blink the LED on start
#define LOOP_DUR_DEFAULT 50
- Duration of time between ADC checks and other loop functions
#define TRG_DUR_DEFAULT 20
- Duration of the Z-axis pulse sent, in ms
#define HYST_DEFAULT 20
- Software hysteresis for ADC/DAC adjustment, in mV (±20 default)
extern long voltMeterConstant = 1125300L;
- For fine tuning input voltage sense
extern byte pP_i2c_address = 0xa0;
- I2C Bus Slave Address